• Link to Instagram
  • Link to Facebook
  • Link to LinkedIn
  • Link to Pinterest
  • Service and Parts
Sales 303.766.3646 | Service 800.566.9953
ASI Dental
  • About
    • About
    • Careers with ASI
    • ASI Difference
  • Reviews
    • Customer Reviews
  • Products
    • ASI Products
  • Design
    • Architectural Office Plan
    • Architects and Designers
    • Office Planning Guide
    • Gallery
    • ASI Color Selection Guide
  • FAQs/Education
    • FAQs
    • Residency Programs
    • ASI Dental Articles
    • Equipment Tips
  • Purchase
    • How to Buy
    • Financing
    • Government Purchasing
    • Order Terms & Conditions
    • Warranty
    • Showroom Specials
  • Service/Parts
    • Support
  • Contact Us
    • Sales
    • Feedback
    • Careers
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
ASIDesign

About ASIDesign

This author has not written his bio yet.
But we are proud to say that ASIDesign contributed 16 entries already.

Entries by ASIDesign

Glider Surgical Table Built-In Nitrous Oxide Sedation System

October 21, 2026/in Articles/by ASIDesign

You can bring nitrous oxide sedation directly to The Glider® Surgical Table. Using the Glider’s integrated accessory rail, popular nitrous oxide systems, including Accutron, Porter, and Belmont, mount directly to the side of the table. This eliminates the need for a separate nitrous cart or rear cabinet. Each installation includes custom brackets for the displays […]

Glider Surgical Table Gets a Mobility Upgrade

September 17, 2026/in Articles/by ASIDesign

We’ve made an important update to the Glider surgical delivery system. The redesigned angled legs, paired with higher-performance five-inch casters featuring sealed precision bearings, transform how smoothly the system moves in your operatory. If you’ve worked with a surgical table in a busy practice, you know the challenge. Maneuvering around patient chairs and tight operatory […]

Beyond Over-the-Patient: Cart-Based Dental Systems

June 19, 2025/in Articles/by ASIDesign

Dental handpiece delivery has evolved over the last fifty years, moving away from side pedestal-mounted units with standing procedures. As the dental industry adopted “sit down” dentistry as a standard, the dental unit remained in the same position with a post and a horizontal arm replacing where the traditional pedestal unit was previously. As a […]

The Modern ASI Dental Junction Box

September 18, 2024/in Articles/by ASIDesign

Select from a variety of esthetic options that provide an effective manner to combine utilities, foot control connections and data cable management into one comprehensive system. Learn more about how they function and best placement for use in your style of dental operatory and equipment. What is a Dental Junction Box? Historically junction boxes provided […]

What’s the Best Water for My Dental Unit

April 23, 2021/in Articles/by ASIDesign

Given the many different water options to use in your dental unit, it can be perplexing to know which one works best. Should you use the artisanal water filtered through ancient volcanic rock deep beneath Mount Fuji, or will simple municipal tap water suffice? The confusion arises from the dual requirement that the dental office […]

How to Select the Best Specialty Dental Patient Chair for Your Practice

February 10, 2021/in Articles/by ASIDesign

Although patient comfortability is a concern, close access to the patient oral cavity is essential for improved treatment and ergonomics for the dentist. The primary purpose of the dental patient chair is to deliver the oral cavity to the dentist in a stable and ergonomic fashion. All chair design considerations should be based on maintaining […]

Importance of Properly Maintaining Handpieces and Quick Connect Couplers

July 28, 2020/in Articles/by ASIDesign

A common issue that can occur with dental equipment is a loss of pressure or torque from air-driven high-speed handpieces. High-speed handpieces use miniature turbines that look like small water wheels in the head and spin around from the compressed air. The air goes up one side of the handpiece, spins the turbine, then returns […]

Update on Molecular Iodine Compatibility

June 3, 2020/in Articles/by ASIDesign

We mentioned in early May that we would evaluate the equipment compatibility of molecular iodine if it were placed in the water bottle system for handpiece irrigation. We used the IORinse Concentrate that is made by IOTechInternational. We tested using both a 50% concentrate with water and 100% concentrate. By comparison, the manufacturer recommends a […]

Assessing the Impact of “Should” vs. “Shall” on Your Practice

June 3, 2020/in Articles/by ASIDesign

The difference between “Should” and “Shall” in Regulatory Speak can make a big difference in how you go about interpreting the many new guidelines coming out regarding infection control. The rush of new recommendations coming out has been not only confusing with a lack of clarity but also sometimes contradictory. To add to the confusion, […]

Disinfecting Your ASI Waterlines

April 28, 2020/in Articles/by ASIDesign

The following is a primer on waterline disinfection and current recommendations for protocol. Why You Need to do Waterline Disinfection Even though modern dental units have non-retracting water valves inside, bacteria will always find its way into the waterline necessary to begin building a biofilm matrix. Many assume if the city water has diluted chlorine […]

Page 1 of 212

Archives

  • November 2026 (1)
  • October 2026 (1)
  • September 2026 (1)
  • June 2025 (1)
  • September 2024 (1)
  • April 2021 (1)
  • February 2021 (1)
  • July 2020 (1)
  • June 2020 (2)
  • April 2020 (1)
  • December 2019 (1)
  • June 2019 (2)
  • November 2017 (1)
  • August 2017 (1)
  • December 2015 (1)
Copyright © 2026 ASI Dental. All rights reserved.
  • Link to Instagram
  • Link to Facebook
  • Link to LinkedIn
  • Link to Pinterest
  • Contact Us
  • Privacy Policy
  • Order Terms
  • Website Terms
  • FAQ
Scroll to top Scroll to top Scroll to top